Absopulse Introduces Redundant, Rack-mount AC-DC Power System with Plug-in Modules
Absopulse introduced the PFC 419F-5K-4U19 Series, with a modular, rack-mount ac-dc power system with power factor corrected input. It is suitable for many heavy-duty applications including power utilities, telecommunications and in industrial control.
The system is constructed with up to five 1kW plug-in power supply modules assembled in a 4U x 19 x 15" card-frame. Each 4U x 16HP x 304mm plug-in module has a built-in redundancy diode for parallel connection or N+1 redundant operation, including hot-insertion. The redundancy diode also allows for a battery to be connected to the output for back-up purposes. The fully loaded PFC 419F-5K-4U19 system delivers a maximum of 5 or 4kW with N+1 redundancy.
The plug-in modules each employ a power factor corrected input and a following half-bridge stage to convert the universal ac-input voltage (95-264Vac) to 24Vdc, 48Vdc, 110Vdc or 125Vdc. Custom input/output voltages are available. The modules include a module fail alarm with optocoupler output, summarized into a single Form C alarm on the shelf motherboard. The front panel of every module has an output ON LED indicator. Test points for monitoring output voltage and voltage adjustment potentiometers are available as options.
The plug-in modules comply with EN/UL60950 and equivalent industrial safety standards and the EN61000-3-2 directive for low input harmonic distortion. They are filtered to meet EN55022-A EMI standards with large margins. Efficiency at full load is typically 80%. Protection features include 4300Vdc input to output isolation, output current limiting with short-circuit protection and thermal shutdown with self-resetting. Cooling is by two high quality built-in fans on each plug-in module.
Share this story
Send via E-mail
Post to Twitter
On the Web:
White Papers
March 11, 2013
Power Modules for Charger Applications
Sponsored by Vincotech
February 27, 2013
The Adaptive Cell Converter Topology Enables Constant Efficiency Over Universal Input AC Line in Front-End, High-Density Power Factor Correction Applications
Sponsored by Vicor Corp.
February 27, 2013
From 48 V direct to Intel VR12.0: Saving "Big Data" $500,000 per datacenter, per year
Sponsored by Vicor Corp.
More White Papers
- Altera Acquires Enpirion for $140 Million, Forms Power Business Unit
- Ericsson Saves Board Space with Surface-Mount Digital Bus Converter
- SiC Modules, IGBTs and Super-Junction MOSFETs Introduced on Day One of PCIM
- SiC and GaN Again a Major Focus at PCIM Europe
- PowerbyProxi Joins Wireless Power Consortium
- Vincotech and Infineon Introduce New Packaging Options at PCIM Europe
- Bosch Claims First Sub-$450 240V EV Charging Station
- Eaton and CA Technologies Join to Deliver Infrastructure Management for Data Centers
- DOE Selects Consortium to Develop Next-Generation Batteries for Automobiles
- Dana Receives Grant from NRCan to Improve Thermal Management for EV Battery Packs
- Power-One Gets $1 Billion – ABB Gets Inverters
- Renesas Adds IGBT Drivers with Micro-Isolator for Electric and Hybrid Vehicle Inverters
- European Project Reports Achievements in Drive to Shape the Future of Power Microelectronics
- Bosch Claims First Sub-$450 240V EV Charging Station
- Eltek Signs Agreement with Caterpillar on Telecom Hybrid Systems
- LED Lighting Power & Dimming Controls Introduced by Phihong
- Digitally-Isolated Gate Drivers Provide Robust Drop-in Replacements for Opto-Drivers
- Power-One Q1 2013 Results include 4 Cents-per-Share Loss due to Synqor Litigation
- Europeans Establish Dueling Projects to Advance Power Electronics Technologies
- Fairchild's Integrated Low-Side Gate Driver Incorporates 3.3-V LDO in 5-Lead SOT-23
- Green Building Power Forum 2010: Fujitsu Components America
- Darnell's Digital Power Forum 2009: CUI Incorporated
- Green Building Power Forum 2010: EMerge Alliance
- Green Building Power Forum 2010: Anderson Power Products
- Green Building Power Forum 2009: Independence Station
- Darnell's Digital Power Forum 2009: Coilcraft
- Darnell's Digital Power Forum 2009: Champs Technologies
- Darnell's Digital Power Forum 2009: EXAR Corporation
- Darnell's Digital Power Forum 2009: PMBus
- Darnell's Digital Power Forum 2009: Power Plaza
Design Features
October 22, 2012
Energy Efficiency with Class D Amplifier Modules
Class-D switching amplifiers are helping audio designers create personal multimedia devices and home audio/visual systems that demonstrate how compact and stylish equipment can also deliver high sound quality and high audio output power. The key to this breakthrough, providing freedom from the large and bulky boxes housing traditional audio products, lies in the class-D amplifier’s high energy efficiency, which is typically around 90%. This allows designers to reduce or eliminate heatsinks as well as using smaller-sized PCBs and smaller components such as transformers, connectors and power supplies.
Design Features
October 8, 2012
The Role of Hall Effect Sensors in Power Distribution Infrastructure
Power distribution units (PDUs) form an essential part of modern computing and data communications hardware. They provide multiple outputs for transferring electrical power with maximum efficiency, controlling the power capacity and safeguarding against the possible causes of supply interruption. With an ever increasing need from tech savvy consumers for higher data throughput and greater quantities of data storage capacity, as well as tough international legislation now governing CO&sub2; emissions, the demands being placed on these units are proving challenging for engineering teams to satisfy.
Product Focus
August 13, 2012
The Year in AC-DC Power Supply Technology
The past year witnessed significant new product releases, technological developments, and industry news related to the field of AC-DC Power Supply technology.
.gif)


.gif)