June 27, 2012

Emerson Increases Capacity of Liebert NX UPS Product Line

Power Channels: Power Components

Emerson Network Power has added new, higher-capacity models to the transformer-free Liebert NX family of double conversion UPS systems with today’s release of the Liebert NX 225-600 kVA UPS. The UL-listed Liebert NX 225-600 kVA is available for global regions with 480V, 60 Hz applications, including North America, Central and South America, the Philippines, Taiwan and Korea.

The scalable UPS system offers mid-to–large-sized data centers a backup power solution that provides the flexibility to grow incrementally without requiring infrastructure renovations. Softscale™ technology allows the Liebert NX 225-600 kVA to be sized to current power requirements and easily scaled up to a larger capacity with a simple software key, which is a more reliable method than adding hardware to grow the module rating. It offers IT managers an economical expansion path for data center growth without adding to the UPS footprint.

ADVERTISEMENT

The Liebert NX 225-600 kVA transformer-free UPS operates at extremely high efficiency, resulting in lower utility costs. In normal, double-conversion mode, the Liebert UPS operates at 95 percent or higher efficiency during typical 40 percent - 80 percent loading. During Intelligent Eco-mode™ operation, the Liebert NX 225-600 kVA UPS operates at efficiencies up to 99 percent. This high efficiency operating mode is standard on each system and enables the unit to run on bypass power during customer-defined conditions. This no-break mode is optimized for the Liebert NX design by maintaining power to the rectifier, and keeping the inverter energized and synchronized with the input for fast, no-break return to full double-conversion mode.

"IT and facility managers are continually dealing with rapid and unpredictable compute growth, while being forced to work within limited budgets and a fixed floor space," said Peter Panfil, vice president of global power, Emerson Network Power. "The Liebert NX 225-600 kVA is a solid investment that helps prepare data center managers for what’s next while providing an economical growth path for tomorrow’s computing needs. It provides high efficiency in both normal and Intelligent EcoMode operation – and superior reliability and availability needed to meet growing demand."

The Liebert UPS features a real-time, menu-driven touch-screen display panel that monitors a variety of operating parameters, including unit metering and status information. The Liebert NX also can be centrally-monitored and managed through an optional Liebert SiteScan® software interface. Data also may be directly output to a network for integration with other monitoring systems, including building management systems.

Opinion: Unraveling the Ultra-Low Power Design Issues

The Liebert NX features optional matching battery cabinets that can be equipped with Alber® BDSi™ integrated battery monitoring to proactively monitor battery health, allowing proactive battery replacement and optimized availability.

To further ensure the health of the system, the Liebert NX 225-600 kVA UPS can be remotely monitored through Life.net™, and the Emerson Network Power Liebert Services 24/7 service center. This service provides pre-emptive notification of more than 150 operating parameters, immediate identification of problems and a detailed reporting of power and equipment trends. Life.net monitoring is provided standard for the first year of operation.

Share this story

Send via E-mail
Post to Twitter

On the Web:

Emerson

ADVERTISEMENT

White Papers

March 11, 2013

Power Modules for Charger Applications

Sponsored by Vincotech

February 27, 2013

The Adaptive Cell Converter Topology Enables Constant Efficiency Over Universal Input AC Line in Front-End, High-Density Power Factor Correction Applications

Sponsored by Vicor Corp.

February 27, 2013

From 48 V direct to Intel VR12.0: Saving "Big Data" $500,000 per datacenter, per year

Sponsored by Vicor Corp.

More White Papers

Most Popular

Design Features

October 22, 2012

Energy Efficiency with Class D Amplifier Modules

Class-D switching amplifiers are helping audio designers create personal multimedia devices and home audio/visual systems that demonstrate how compact and stylish equipment can also deliver high sound quality and high audio output power. The key to this breakthrough, providing freedom from the large and bulky boxes housing traditional audio products, lies in the class-D amplifier’s high energy efficiency, which is typically around 90%. This allows designers to reduce or eliminate heatsinks as well as using smaller-sized PCBs and smaller components such as transformers, connectors and power supplies.

Read this paper

Design Features

October 8, 2012

The Role of Hall Effect Sensors in Power Distribution Infrastructure

Power distribution units (PDUs) form an essential part of modern computing and data communications hardware. They provide multiple outputs for transferring electrical power with maximum efficiency, controlling the power capacity and safeguarding against the possible causes of supply interruption. With an ever increasing need from tech savvy consumers for higher data throughput and greater quantities of data storage capacity, as well as tough international legislation now governing CO&sub2; emissions, the demands being placed on these units are proving challenging for engineering teams to satisfy.

Read this paper

Product Focus

August 13, 2012

The Year in AC-DC Power Supply Technology

The past year witnessed significant new product releases, technological developments, and industry news related to the field of AC-DC Power Supply technology.

Read this paper

Read More Technical Features

 

©2013 Darnell Group Inc.