Ericsson Shows How Dynamic-Bus Architecture Saves Energy in Datacenters

Ericsson has laid out its vision to system architects developing equipment for computing-intensive environments such as datacenters. The increasing demand for more Internet services and cloud computing is driving both the expansion and building of new datacenters around the world. A key challenge for operators is the minimization of energy expenditure at the board level. Ericsson believes that a significant aid to this process is the use of advanced Dynamic Bus Voltage architectures. This vision was presented by Ericsson at last month's Electronics Goes Green (EGG) congress in Berlin.

Recommended: Altera Acquires Enpirion for $140 Million, Forms Power Business Unit

Today, the standard power architecture increasingly being used is the Intermediate Bus Architecture (IBA), which uses intermediate bus converters (IBCs) to convert a traditional 48 VDC distribution-level power line used in telecoms to typically a static 12 VDC. This first "down-conversion" 12V level feeds a number of DC/DC point-of-load (POL) regulators, which supply the final load voltages at a chip's logic supply levels of 3V or below. The choice of 12 VDC has been made to ensure a high enough voltage to deliver all the power required by the board, or load, in times of high data traffic. However, this approach becomes highly inefficient when the traffic demand is low.

ADVERTISEMENT

The Dynamic Bus Voltage is an evolution of the Intermediate Bus Architecture and provides the possibility to dynamically adjust the power envelope to meet load conditions. It achieves this by adjusting the intermediate bus voltage, previously the 12 VDC fixed bus voltage, via the use of advanced digital power control and optimized hardware combined with an energy-optimizer series of algorithms. This can lead to reductions in both energy consumption and power dissipation, which in turn contributes to a reduction in the amount of cooling that is required.

Related: Eaton and CA Technologies Join to Deliver Infrastructure Management for Data Centers

"Dynamic Bus Voltage is a technology that makes possible to reduce board power consumption from anywhere between 3 and 10 percent, depending on the board application," said Patrick Le Fèvre, Marketing and Communication Director, Ericsson Power Modules. "The potential for energy saving is a very substantial one, especially when taking into account the fact that 1W saved at the board level can result in a 3W saving at the power grid level."

Ericsson 3E* BMR456-DBV and BMR457-DBV Advanced Bus Converters offer unprecedented performance and flexibility to system architects developing equipment for information and communication technologies (ICT) requiring smart and efficient board power solutions. Both of these products feature the "Ericsson DC/DC Energy Optimizer firmware" implemented in ARM microprocessor technology which enables a significant contribution to the reduction of power consumption. Hardware and firmware optimized to meet the demands of the Dynamic Bus Voltage (DBV) power architecture, the output voltage of the quarter-brick BMR456-DBV can be adjusted within an operation range of 13.0V to 8.2V, and with the full benefits of the Ericsson DC/DC Energy Optimizer technology, but furthermore adjusted down to 4V to power ultimate below 5V Sleep Mode configuration, which today requires an extra power-module.

Opinion: Maximising Synergies between Power Electronics and ICT for improving Energy Efficiency

Designed for smaller systems, the eighth-brick-format BMR457-DBV full operational output voltage is optimized to deliver high performance from 13.2V to 8.2V and can be adjusted down to 6.9V making it possible to power the mid-power range of applications requiring 6V Sleep Mode configuration. In both products, the output voltage can be adjusted via PMBus commands or preset profiles stored by the system designer in the built-in USER_STORE memory block, making it simple to adjust the intermediate board bus voltage to a level that will guarantee the lowest power consumption.

In addition, embedding industry-first technology and Ericsson IP, the Ericsson DC/DC Energy Optimizer not only permanently optimizes switching parameters to reduce energy consumption, but also offers a large number of features including the ability to handle input voltage transients with slew-rates up to 0.5 V/µs, while keeping the output voltage within +/-10 percent. This ensures that the output voltage does not trigger over-voltage protection. It also very efficiently manages pre-bias start-up operation and shut down is fully controlled avoiding voltage spikes that cause avalanche conditions in the secondary-side synchronous rectification MOSFET, making a contribution to further improve reliability.

Share this story

Send via E-mail
Post to Twitter

On the Web:

Ericsson Power Modules

ADVERTISEMENT

White Papers

March 11, 2013

Power Modules for Charger Applications

Sponsored by Vincotech

February 27, 2013

The Adaptive Cell Converter Topology Enables Constant Efficiency Over Universal Input AC Line in Front-End, High-Density Power Factor Correction Applications

Sponsored by Vicor Corp.

February 27, 2013

From 48 V direct to Intel VR12.0: Saving "Big Data" $500,000 per datacenter, per year

Sponsored by Vicor Corp.

More White Papers

Most Popular

Design Features

October 22, 2012

Energy Efficiency with Class D Amplifier Modules

Class-D switching amplifiers are helping audio designers create personal multimedia devices and home audio/visual systems that demonstrate how compact and stylish equipment can also deliver high sound quality and high audio output power. The key to this breakthrough, providing freedom from the large and bulky boxes housing traditional audio products, lies in the class-D amplifier’s high energy efficiency, which is typically around 90%. This allows designers to reduce or eliminate heatsinks as well as using smaller-sized PCBs and smaller components such as transformers, connectors and power supplies.

Read this paper

Design Features

October 8, 2012

The Role of Hall Effect Sensors in Power Distribution Infrastructure

Power distribution units (PDUs) form an essential part of modern computing and data communications hardware. They provide multiple outputs for transferring electrical power with maximum efficiency, controlling the power capacity and safeguarding against the possible causes of supply interruption. With an ever increasing need from tech savvy consumers for higher data throughput and greater quantities of data storage capacity, as well as tough international legislation now governing CO&sub2; emissions, the demands being placed on these units are proving challenging for engineering teams to satisfy.

Read this paper

Product Focus

August 13, 2012

The Year in AC-DC Power Supply Technology

The past year witnessed significant new product releases, technological developments, and industry news related to the field of AC-DC Power Supply technology.

Read this paper

Read More Technical Features

 

©2013 Darnell Group Inc.