ENERGY STAR Computer Servers Version 2.0 Specification Published

The U.S. Environmental Protection Agency (EPA) has published the Final Version 2.0 ENERGY STAR Servers Specification and the Final ENERGY STAR Servers Test Method. EPA and The U.S. Department of Energy (DOE) would like to thank the many stakeholders who have invested time and effort over the past year to contribute feedback to this specification revision process.

The Version 2.0 Specification introduces new Active State Efficiency criteria, requiring all server products to run the Standard Performance Evaluation Corporation's (SPEC) Server Efficiency Rating Tool (SERT) and report the results. These results will be used in a later Version 3.0 Specification to set active efficiency levels. It also greatly increases the scope of products covered, now including the majority of the server market by adding blade, multi-node, and resilient servers on top of existing coverage of rack and pedestal servers from Version 1.0.

ADVERTISEMENT

In addition, this specification: Introduces a new approach to product families that requires significantly fewer tests of individual configurations to qualify. Cuts memory adders by more than half, to reflect rapid improvements in this component’s energy efficiency, and maintains rigorous idle power requirements for one and two socket rack and pedestal servers. Includes the option of testing systems with Auxiliary Processing Accelerators (APAs), allowing systems to be shipped with GPGPUs or similar components. Allows products with 3 phase power supplies to qualify. And updates requirements for power and temperature sampling, including an allowance for systems that implement time stamping of data.

Related: Acopian Adds Array of Options to Low-Profile AC-DC and DC-DC Power Supplies

Changes to the Version 2.0 Specification from the Final Draft include: An expansion of the rounding rules for blade chassis. Based on stakeholder input on the Final Draft, EPA and DOE have relaxed the requirements to allow for rounding to the nearest power domain. An expansion of form factor restrictions in product families, to enable products that differ only by superficial mechanical differences to be qualified within the same product family. And changed Section 4.1 to detail general reporting rather than focus on the PPDS, as EPA does not intend to use the PPDS for Version 2.0.

Changes to the Version 2.0 Test Method from the Final Draft include: Additional three-phase voltages for the European Market. Based on stakeholder input on the Final Draft, DOE has included 400 V ac 50 Hz in the list of supply voltages for European market. Input frequency option of 50 Hz or 60 Hz for the Japanese market to reflect the voltage standards of Japan. The same expansion of rounding rules for blade chassis as stated in the Specification. Change in section 5.2 F) to clarify that the controller system and the Unit Under Test (UUT) should be connected to the same network switch and must be configured to communicate via the network. Change in section 5.1 J) to ensure that the UUT offers at least one Ethernet port for the purpose of testing. Based on stakeholder input DOE has deleted the requirement of setting up the UUT with minimal I/O add-in cards. And general Test Method updates to be consistent with SERT requirements.

Opinion: Maximising Synergies between Power Electronics and ICT for improving Energy Efficiency

EPA shares its partners' desire for a smooth transition from one ENERGY STAR specification to the next, so that users can expect ENERGY STAR labeled products to fully meet the latest requirements upon their effective date. With this in mind, EPA has established the following timeline: Effective today, manufacturers may begin testing eligible products against the Version 2.0 requirements. On the week of March 18th, the QPX forms will be distributed to stakeholders for review. By April 5th, manufacturers and Certification Bodies (CBs) should submit comments on the QPX forms, for review by EPA In April, EPA will finish creating the data submission forms for CBs. CBs must successfully complete a test submission in order to retain their ENERGY STAR recognition. Once the above are completed, product test results will begin appearing on the ENERGY STAR website.

After August 30th, CBs will be instructed to stop certifying new product submittals to the Version1.1 specification. Existing certification to Version 1.1 will remain valid for purposes of ENERGY STAR qualification until December 16, 2013. In September, EPA will organize an "off-season" meeting to review SERT data submission and discuss a variety of topics relating to future versions of the servers specification.

As of December 16, 2013, all servers will have to meet the Version 2.0 requirements to bear the ENERGY STAR mark. All certifications of products to the Version 1.1 specification will be invalid for purposes of ENERGY STAR qualification.

Share this story

Send via E-mail
Post to Twitter

On the Web:

ENERGY STAR Program

ADVERTISEMENT

White Papers

March 11, 2013

Power Modules for Charger Applications

Sponsored by Vincotech

February 27, 2013

The Adaptive Cell Converter Topology Enables Constant Efficiency Over Universal Input AC Line in Front-End, High-Density Power Factor Correction Applications

Sponsored by Vicor Corp.

February 27, 2013

From 48 V direct to Intel VR12.0: Saving "Big Data" $500,000 per datacenter, per year

Sponsored by Vicor Corp.

More White Papers

Most Popular

Design Features

October 22, 2012

Energy Efficiency with Class D Amplifier Modules

Class-D switching amplifiers are helping audio designers create personal multimedia devices and home audio/visual systems that demonstrate how compact and stylish equipment can also deliver high sound quality and high audio output power. The key to this breakthrough, providing freedom from the large and bulky boxes housing traditional audio products, lies in the class-D amplifier’s high energy efficiency, which is typically around 90%. This allows designers to reduce or eliminate heatsinks as well as using smaller-sized PCBs and smaller components such as transformers, connectors and power supplies.

Read this paper

Design Features

October 8, 2012

The Role of Hall Effect Sensors in Power Distribution Infrastructure

Power distribution units (PDUs) form an essential part of modern computing and data communications hardware. They provide multiple outputs for transferring electrical power with maximum efficiency, controlling the power capacity and safeguarding against the possible causes of supply interruption. With an ever increasing need from tech savvy consumers for higher data throughput and greater quantities of data storage capacity, as well as tough international legislation now governing CO&sub2; emissions, the demands being placed on these units are proving challenging for engineering teams to satisfy.

Read this paper

Product Focus

August 13, 2012

The Year in AC-DC Power Supply Technology

The past year witnessed significant new product releases, technological developments, and industry news related to the field of AC-DC Power Supply technology.

Read this paper

Read More Technical Features

 

©2013 Darnell Group Inc.